Technical Overview

Diaphragm valves require differential pressure to open and close. When closing, the valve’s electronically controlled diverter directly connects the upper chamber of the valve to the inlet pressure. The inlet pressure, with the help of the spring, pushes the diaphragm down, sealing it against the valve body to stop the flow of water out of the valve outlet.

Schematics

CLOSED POSITION

OPEN POSITION